Stuxnet Infections Exposed Windows and Siemens Industrial Controller Risks

Active Exploitation · 3 sources · Updated 2mo ago · First seen Jan 24, 2011

Stuxnet Infections Exposed Windows and Siemens Industrial Controller Risks

Siemens reported that 24 industrial customers worldwide had disclosed Stuxnet infections as of March 11, 2011. The malware was removed in every reported case, with no reported adverse impact on those customers’ automation solutions. Siemens described Stuxnet’s attempts to insert program blocks into SIMATIC CPU 315-2 controllers and its potential modification of the DB8061 data block in CPU 417 projects, highlighting the need to verify controller integrity rather than limit remediation to infected Windows computers.

Stuxnet also exploited CVE-2010-3888, a local privilege-escalation vulnerability affecting 32-bit Microsoft Windows platforms, in the wild in July 2010. The supplied CVE record does not identify specific affected Windows versions, attack mechanics, severity scores, or remediation; Microsoft’s MS10-046 bulletin is another associated security reference. Siemens recommended comprehensive malware scanning, isolation of infected computers, installation of Microsoft and SIMATIC security updates, and removal using Sysclean. Its guidance also called for checking removable media and external connections, maintaining antivirus protection, and restoring affected plant control systems to their original state when unauthorized controller blocks were detected.

This is being exploited nowSee which actors are running it and whether you're in range.
Check your exposure
Event timeline

How this story unfolded

Events from the most recent confirmed update back to the earliest known activity.

5 events · Jul 2010 – Jan 24, 2011
  1. Reported Jan 24, 201116y ago

    Siemens details Stuxnet's controller modifications and recovery guidance

    Siemens described Stuxnet's attempts to insert DB890, FC1865, and FC1874 into SIMATIC CPU 315-2 controllers, and its potential modification of DB8061 in CPU 417 projects during download. Siemens urged restoration of affected plant control systems when unauthorized Stuxnet blocks were detected.

    SIMATIC WinCC / SIMATIC PCS 7: Information about Malware / Viruses / Trojan horses - ID: 43876783 - Industry Support Siemens
  2. Reported Jan 24, 201116y ago

    Siemens reports 24 industrial customers affected by Stuxnet

    As of March 11, 2011, Siemens reported that 24 industrial customers worldwide had reported Stuxnet infections. Siemens said the malware had been removed in every reported case and none of the infections had adversely affected the customers' automation solutions.

    SIMATIC WinCC / SIMATIC PCS 7: Information about Malware / Viruses / Trojan horses - ID: 43876783 - Industry Support Siemens
  3. Jan 24, 201116y ago

    Siemens updates SIMATIC Security Update V1.0 SP1

    Siemens updated SIMATIC Security Update V1.0 SP1 and provided it for download. The update checks for the Microsoft security patch and adjusts Windows icon protection accordingly.

    SIMATIC WinCC / SIMATIC PCS 7: Information about Malware / Viruses / Trojan horses - ID: 43876783 - Industry Support Siemens
  4. Oct 8, 201016y ago

    CVE-2010-3888 record published

    The CVE-2010-3888 record was published and updated on October 8, 2010, documenting the Windows privilege-escalation vulnerability exploited by Stuxnet. The record credits Kaspersky Lab researchers and other researchers with identifying it.

    CVE Record: CVE-2010-3888
  5. Jul 2010

    Stuxnet exploits Windows privilege-escalation vulnerability in the wild

    Stuxnet exploited CVE-2010-3888 in July 2010. The vulnerability allowed local users on 32-bit Microsoft Windows platforms to gain elevated privileges through unspecified attack vectors.

    CVE Record: CVE-2010-3888
Linked entities

Related entities

Vulnerabilities, threat actors, malware, products, organizations, and breaches Mallory has linked to this story.

Open in app →

Malware

1 linked

Affected products

2 linked
WindowsSimatic Wincc

Organizations

1 linked
Siemens
Do you run this?Correlate live exploitation activity against the software you actually run, and see where you're exposed.
See Who's Exploiting This
Mallory platform

See the full picture, correlated to your attack surface.

This page covers what’s public. Mallory adds the parts that aren’t: which of your assets are affected, which threat actors are using it right now, and what to deploy next.

Exposure mappingMap indicators from this story to your assets and identify affected systems in minutes.
Threat actor evidenceEvery observed campaign, victim, and pivot linked to actors named in this story.
Associated malwareMalware, exploits, and IOCs connected to the activity described here.
Detection signaturesYARA, Sigma, and Snort rules deployed to your SIEM as soon as they’re published.
Scheduled alertsGet matching new stories delivered to your team as they break, not the next morning.
AI threadsAsk questions about this story and take action on the answers.