CVE-2014-2364: Stack-based Buffer Overflow in Advantech WebAccess ActiveX Controls
- Vendor
- Advantech
CVE-2014-2364 is a stack-based buffer overflow vulnerability in Advantech WebAccess before version 7.2. The flaw exists in multiple ActiveX controls (webvact.ocx, dvs.ocx, webdact.ocx) and can be triggered by sending a long string to parameters such as ProjectName, SetParameter, NodeName, CCDParameter, SetColor, AlarmImage, GetParameter, GetColor, ServerResponse, SetBaud, or IPAddress. Remote attackers can exploit this vulnerability to execute arbitrary code in the context of the user running the affected ActiveX control.
Impact, mitigation & remediation
What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.
Impact
What an attacker gets, and what they’ve been doing with it.
Successful exploitation allows remote code execution with the privileges of the user running the vulnerable ActiveX control, potentially leading to full system compromise. The vulnerability is remotely exploitable and public exploits are available, increasing the risk of widespread exploitation, especially in critical infrastructure environments where Advantech WebAccess is deployed.
Mitigation
If you can’t patch tonight, do this now.
In addition to patching, restrict network access to systems running Advantech WebAccess, isolate SCADA/HMI systems from the Internet, and use VPNs for remote access. Disable or remove unnecessary ActiveX controls and enforce least privilege for user accounts running the software.
Remediation
Patch, then assume compromise.
Upgrade Advantech WebAccess to version 7.2 or later, which addresses this vulnerability. Ensure all affected ActiveX controls are updated on all systems.
Exploits
1 exploit validated by Mallory's analysis.
Affected products & vendors
Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.
References
Frequently asked questions
- Is CVE-2014-2364 exploited in the wild?
- As of Oct 16, 2026, Mallory has no reports of CVE-2014-2364 being exploited in the wild. It is not listed in CISA KEV.
- Is there a public exploit for CVE-2014-2364?
- Yes. Mallory tracks 1 public exploit or proof of concept for CVE-2014-2364, the earliest disclosed Jul 17, 2014.
- Is there a patch for CVE-2014-2364?
- Upgrade Advantech WebAccess to version 7.2 or later, which addresses this vulnerability. Ensure all affected ActiveX controls are updated on all systems.
- What products are affected by CVE-2014-2364?
- Advantech Webaccess.
- How severe is CVE-2014-2364?
- CVE-2014-2364 has a CVSS v2 score of 7.5 (High) and an EPSS score of 61.4% (99th percentile) as of Oct 16, 2026.
Recent activity
No public activity tracked yet. Mallory keeps watching.
No public activity observed for this vulnerability.