CVE-2016-10760: Command Injection in Seowon Intech routers diagnostic.cgi
- Vendor
- Seowon Intech Inc
A command injection vulnerability exists in Seowon Intech routers within the diagnostic.cgi script. The vulnerability is due to improper sanitization of user-supplied input in the 'ping_ipaddr' parameter, allowing attackers to inject arbitrary shell commands via shell metacharacters.
Impact, mitigation & remediation
What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.
Impact
What an attacker gets, and what they’ve been doing with it.
Successful exploitation allows remote attackers to execute arbitrary commands on the router with the privileges of the web server process, potentially leading to full device compromise, unauthorized access, and further network penetration.
Mitigation
If you can’t patch tonight, do this now.
Restrict access to the web management interface to trusted networks, use strong authentication, and consider disabling diagnostic.cgi if not required until a patch is available.
Remediation
Patch, then assume compromise.
Update the router firmware to a version that properly sanitizes input to diagnostic.cgi, specifically ensuring that the 'ping_ipaddr' parameter is validated and shell metacharacters are filtered or rejected.
Exploits
No public exploits tracked yet. Mallory keeps watching.
Affected products & vendors
Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.
Frequently asked questions
- Is CVE-2016-10760 exploited in the wild?
- Yes. As of Oct 16, 2026, Mallory has reports of exploitation in the wild.
- Is there a public exploit for CVE-2016-10760?
- Yes. As of Oct 16, 2026, Mallory has reports of a public exploit for CVE-2016-10760.
- Is there a patch for CVE-2016-10760?
- Update the router firmware to a version that properly sanitizes input to diagnostic.cgi, specifically ensuring that the 'ping_ipaddr' parameter is validated and shell metacharacters are filtered or rejected.
- What products are affected by CVE-2016-10760?
- Seowon Intech Inc Swr-300a Firmware, Seowon Intech Inc Swr-300b Firmware, Seowon Intech Inc Swr-300bg Firmware, and Seowon Intech Inc Swr-300c Firmware.
- How severe is CVE-2016-10760?
- CVE-2016-10760 has a CVSS v3 score of 9.8 (Critical) and an EPSS score of 3.3% (89th percentile) as of Oct 16, 2026.
Recent activity
No public activity tracked yet. Mallory keeps watching.
No public activity observed for this vulnerability.