CVE-2016-10760: Command Injection in Seowon Intech routers diagnostic.cgi

Published Jun 11, 2019 · Updated 1 month ago
Trending this weekNot trendingOutside this week’s top 100
Mention activity · 30 daysNo mention activity in the last 30 days.
CVSS9.8Critical · v3
EPSS3.3%89th percentile
CISA KEVNoNot listed
In the wildReported2 exploitation records in Mallory
Vendor
Seowon Intech Inc
IdentifiersCVE-2016-10760CWE-77 · Improper Neutralization of Special…

A command injection vulnerability exists in Seowon Intech routers within the diagnostic.cgi script. The vulnerability is due to improper sanitization of user-supplied input in the 'ping_ipaddr' parameter, allowing attackers to inject arbitrary shell commands via shell metacharacters.

Do you run this?See affected versions in your environment and whether adversaries are exploiting this vulnerability against assets like yours.
Check your exposure
Analyst brief

Impact, mitigation & remediation

What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.

Impact

What an attacker gets, and what they’ve been doing with it.

Successful exploitation allows remote attackers to execute arbitrary commands on the router with the privileges of the web server process, potentially leading to full device compromise, unauthorized access, and further network penetration.

Mitigation

If you can’t patch tonight, do this now.

Restrict access to the web management interface to trusted networks, use strong authentication, and consider disabling diagnostic.cgi if not required until a patch is available.

Remediation

Patch, then assume compromise.

Update the router firmware to a version that properly sanitizes input to diagnostic.cgi, specifically ensuring that the 'ping_ipaddr' parameter is validated and shell metacharacters are filtered or rejected.

Public exploits

Exploits

No public exploits tracked yet. Mallory keeps watching.

View more in app →
No public exploit code observed for this vulnerability. Mallory keeps watching.
Exposure surface

Affected products & vendors

Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.

VendorProductType
Seowon Intech IncSwr-300a Firmwareoperating_system
Seowon Intech IncSwr-300b Firmwareoperating_system
Seowon Intech IncSwr-300bg Firmwareoperating_system
Seowon Intech IncSwr-300c Firmwareoperating_system
FAQ

Frequently asked questions

Is CVE-2016-10760 exploited in the wild?
Yes. As of Oct 16, 2026, Mallory has reports of exploitation in the wild.
Is there a public exploit for CVE-2016-10760?
Yes. As of Oct 16, 2026, Mallory has reports of a public exploit for CVE-2016-10760.
Is there a patch for CVE-2016-10760?
Update the router firmware to a version that properly sanitizes input to diagnostic.cgi, specifically ensuring that the 'ping_ipaddr' parameter is validated and shell metacharacters are filtered or rejected.
What products are affected by CVE-2016-10760?
Seowon Intech Inc Swr-300a Firmware, Seowon Intech Inc Swr-300b Firmware, Seowon Intech Inc Swr-300bg Firmware, and Seowon Intech Inc Swr-300c Firmware.
How severe is CVE-2016-10760?
CVE-2016-10760 has a CVSS v3 score of 9.8 (Critical) and an EPSS score of 3.3% (89th percentile) as of Oct 16, 2026.
Activity feed

Recent activity

No public activity tracked yet. Mallory keeps watching.

View more in app →

No public activity observed for this vulnerability.

Do you run this?See affected versions in your environment and whether adversaries are exploiting this vulnerability against assets like yours.
Check your exposure
Mallory platform

The version that knows your environment.

This page is what’s public. Mallory adds the parts that aren’t: which of your assets are affected, which adversaries are exploiting it right now, and which detections to deploy tonight.
Exposure mappingQuery your assets running an affected version, and investigate the blast radius.
Threat actor evidenceEvery report linking this CVE to a named adversary.
Associated malwareMalware families linked to this CVE, with evidence and IOCs.
Detection signatures1YARA, Sigma, Snort, and vendor rules, auto-deployed to your SIEM.
Vendor-by-vendor mappingCross-references every affected SKU, including bundled OEM variants.
Social activityCommunity discussion across Reddit, Mastodon, and other social sources.