CVE-2017-0146: Microsoft Windows SMBv1 Transaction Race Condition Remote Code Execution
- Vendors
- SiemensMicrosoft Corporation
CVE-2017-0146 is a race condition involving Transaction requests in the Microsoft Windows SMBv1 server that permits remote arbitrary code execution through specially crafted packets. EternalChampion and EternalSynergy exploit this vulnerability. Affected releases include Windows Vista SP2, Windows 7 SP1, Windows 8.1, Windows RT 8.1, Windows 10 initial release and versions 1511 and 1607, Windows Server 2008 SP2 and 2008 R2 SP1, Windows Server 2012 and 2012 R2, and Windows Server 2016. Public exploit implementations can overwrite SMB connection session structures to establish administrator-level access and subsequently execute payloads. Microsoft addressed the vulnerability in security bulletin MS17-010.
Impact, mitigation & remediation
What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.
Impact
What an attacker gets, and what they’ve been doing with it.
An unauthenticated remote attacker can execute arbitrary code on an affected SMBv1 server, compromising system confidentiality, integrity, and availability. Documented exploit implementations achieve administrator/SYSTEM-level execution through SMB session manipulation. On affected Siemens Healthineers systems, exploitation can potentially disrupt ultrasound imaging or image review.
Mitigation
If you can’t patch tonight, do this now.
Disable SMBv1 where operationally feasible. Restrict SMB and NetBIOS exposure with firewalls, particularly TCP ports 139 and 445, and isolate vulnerable devices from potentially infected systems and business networks. Avoid Internet exposure. For affected Siemens medical devices, vendor guidance additionally recommends restricting TCP port 3389. If isolation is impossible, operate devices disconnected from the network only when patient safety and treatment will not be jeopardized, and reconnect after remediation. Assess clinical and operational impacts before implementing controls, and maintain backups and restoration procedures.
Remediation
Patch, then assume compromise.
Apply the applicable Microsoft MS17-010 security update: KB4012598 for Windows Vista SP2 and Windows Server 2008 SP2; KB4012212 or KB4012215 for Windows 7 SP1 and Windows Server 2008 R2 SP1; KB4012213 or KB4012216 for Windows 8.1 and Windows Server 2012 R2; KB4012214 or KB4012217 for Windows Server 2012; KB4012216 for Windows RT 8.1; KB4012606 for the initial Windows 10 release; KB4013198 for Windows 10 version 1511; and KB4013429 for Windows 10 version 1607 and Windows Server 2016. For affected medical devices, obtain and install vendor-approved product-specific fixes through Siemens Healthineers customer support or tested patches through Philips support channels, as applicable.
Exploits
5 exploits validated by Mallory's analysis. Hidden: 1 rejected by Mallory's analysis as not a working exploit; 2 not yet analyzed, such as Exploit-DB entries.
Affected products & vendors
Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.
References
Frequently asked questions
- Is CVE-2017-0146 exploited in the wild?
- Yes. As of Oct 16, 2026, Mallory has reports of exploitation in the wild, and CISA added it to KEV on Mar 25, 2022.
- Is there a public exploit for CVE-2017-0146?
- Yes. Mallory tracks 5 public exploits or proofs of concept for CVE-2017-0146, the earliest disclosed Mar 14, 2017.
- Is there a patch for CVE-2017-0146?
- Apply the applicable Microsoft MS17-010 security update: KB4012598 for Windows Vista SP2 and Windows Server 2008 SP2; KB4012212 or KB4012215 for Windows 7 SP1 and Windows Server 2008 R2 SP1; KB4012213 or KB4012216 for Windows 8.1 and Windows Server 2012 R2; KB4012214 or KB4012217 for Windows Server 2012; KB4012216 for Windows RT 8.1; KB4012606 for the initial Windows 10 release; KB4013198 for Windows 10 version 1511; and KB4013429 for Windows 10 version 1607 and Windows Server 2016. For affected medical devices, obtain and install vendor-approved product-specific fixes through Siemens Healthineers customer support or tested patches through Philips support channels, as applicable.
- What products are affected by CVE-2017-0146?
- Siemens Acuson P300 Firmware, Siemens Acuson P500 Firmware, Siemens Acuson Sc2000 Firmware, Siemens Acuson X700 Firmware, Microsoft Corporation Server Message Block, and 4 more.
- How severe is CVE-2017-0146?
- CVE-2017-0146 has a CVSS v3.1 score of 8.8 (High) and an EPSS score of 89.9% (100th percentile) as of Oct 16, 2026.
Recent activity
15 sources tracked across advisories, community write-ups, and news. New activity surfaces here as Mallory finds it.