CVE-2017-5816: RCE in HPE Intelligent Management Center PLAT 7.3 E0504P04
- Vendor
- Hewlett Packard Enterprise
A remote code execution vulnerability exists in HPE Intelligent Management Center (iMC) PLAT version 7.3 E0504P04. The vulnerability allows an attacker to execute arbitrary code on the affected system remotely, potentially leading to full system compromise.
Impact, mitigation & remediation
What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.
Impact
What an attacker gets, and what they’ve been doing with it.
Successful exploitation allows an unauthenticated remote attacker to execute arbitrary code with the privileges of the iMC service, potentially leading to full compromise of the affected system and lateral movement within the network.
Mitigation
If you can’t patch tonight, do this now.
If immediate upgrade is not possible, restrict network access to the iMC management interface to trusted hosts only, and monitor for suspicious activity. Apply any temporary mitigations or workarounds provided by HPE.
Remediation
Patch, then assume compromise.
Upgrade HPE Intelligent Management Center PLAT to a version newer than 7.3 E0504P04 where this vulnerability is patched. Refer to HPE's official advisory for the fixed version and apply the update as soon as possible.
Exploits
1 exploit validated by Mallory's analysis. Hidden: 1 not yet analyzed, such as Exploit-DB entries.
Affected products & vendors
Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.
References
Frequently asked questions
- Is CVE-2017-5816 exploited in the wild?
- As of Oct 16, 2026, Mallory has no reports of CVE-2017-5816 being exploited in the wild. It is not listed in CISA KEV.
- Is there a public exploit for CVE-2017-5816?
- Yes. Mallory tracks 1 public exploit or proof of concept for CVE-2017-5816, the earliest disclosed May 15, 2017.
- Is there a patch for CVE-2017-5816?
- Upgrade HPE Intelligent Management Center PLAT to a version newer than 7.3 E0504P04 where this vulnerability is patched. Refer to HPE's official advisory for the fixed version and apply the update as soon as possible.
- What products are affected by CVE-2017-5816?
- Hewlett Packard Enterprise Intelligent Management Center.
- How severe is CVE-2017-5816?
- CVE-2017-5816 has a CVSS v3 score of 9.8 (Critical) and an EPSS score of 86.2% (100th percentile) as of Oct 16, 2026.