CVE-2019-12263: TCP Urgent Pointer Race Condition in Wind River VxWorks (URGENT/11)
- Vendors
- NetAppBeldenSiemensSonicwallWind River Systems
CVE-2019-12263 is a race condition in the IPnet TCP component of Wind River VxWorks 6.9.4 and VxWorks 7, included in the URGENT/11 vulnerability set. Improper synchronization between the tNet0 network task and a receiving application can cause TCP Urgent Pointer state confusion. Specially crafted TCP packets with a manipulated Urgent Pointer can trigger a buffer overflow and potentially allow remote arbitrary code execution. Exploitation is timing-dependent, difficult to trigger on single-threaded systems, and unreliable on symmetric multiprocessing targets.
Impact, mitigation & remediation
What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.
Impact
What an attacker gets, and what they’ve been doing with it.
Successful exploitation can corrupt application memory and potentially permit arbitrary code execution on an affected device without authentication or user interaction. Compromise of affected embedded or industrial devices can undermine device integrity and disrupt their operational functions. The race condition makes exploitation unreliable.
Mitigation
If you can’t patch tonight, do this now.
Use external firewalls to block TCP segments with the URG flag set, preventing delivery of the urgent-data traffic used to trigger this flaw. Restrict access to affected devices through network segmentation and allowlisted communication paths, and remove direct Internet exposure. For affected RUGGEDCOM base stations, block TCP traffic to the management interface as the vendor-provided workaround. Use securely configured, updated VPNs where remote access is necessary.
Remediation
Patch, then assume compromise.
Apply the applicable Wind River IPnet source patches or device-manufacturer firmware updates addressing CVE-2019-12263. VxWorks 7 SR620 is identified as unaffected by the URGENT/11 vulnerabilities. Product-specific update targets include Siemens RUGGEDCOM WIN70xx/WIN72xx firmware BS5.2.4624.17; SIPROTEC 5 CP300/CP100 device firmware V8.01 and associated Ethernet communication-module firmware V7.91 or higher; CP200 device and communication-module firmware V7.59; and Siemens Power Meters Series 9410/9810 firmware V2.2.1. Confirm applicability against the exact hardware and firmware revision. For affected Rockwell Automation products, install the product-specific fixed firmware or migrate to recommended replacement hardware where patches are unavailable.
Exploits
No public exploits tracked yet. Mallory keeps watching.
Affected products & vendors
Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.
References
Frequently asked questions
- Is CVE-2019-12263 exploited in the wild?
- Yes. As of Oct 25, 2026, Mallory has reports of exploitation in the wild.
- Is there a public exploit for CVE-2019-12263?
- As of Oct 25, 2026, Mallory has found no public exploit for CVE-2019-12263.
- Is there a patch for CVE-2019-12263?
- Apply the applicable Wind River IPnet source patches or device-manufacturer firmware updates addressing CVE-2019-12263. VxWorks 7 SR620 is identified as unaffected by the URGENT/11 vulnerabilities.
- What products are affected by CVE-2019-12263?
- Wind River Systems Vxworks, NetApp E-Series Santricity Os Controller, Belden Garrettcom Magnum Dx940e Firmware, Belden Hirschmann Hios, Siemens Power Meter 9410 Firmware, and 7 more.
- How severe is CVE-2019-12263?
- CVE-2019-12263 has a CVSS v3.1 score of 8.1 (High) and an EPSS score of 3.2% (88th percentile) as of Oct 25, 2026.
Recent activity
8 sources tracked across advisories, community write-ups, and news. New activity surfaces here as Mallory finds it.