CVE-2019-19492: Default Credentials in FreeSWITCH Event Socket
- Vendor
- Freeswitch
FreeSWITCH versions 1.6.10 through 1.10.1 configure the Event Socket interface with a default password. If this password remains unchanged and the interface is accessible, an attacker who knows the default credential can authenticate without obtaining a deployment-specific secret. The issue also affects the SIP calling component in American Dynamics victor Video Management System versions 5.7 and earlier, which uses a hard-coded password.
Impact, mitigation & remediation
What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.
Impact
What an attacker gets, and what they’ve been doing with it.
The shared default credential undermines authentication to an accessible FreeSWITCH Event Socket interface, allowing unauthorized access to the functionality exposed through that interface. In American Dynamics victor, the affected SIP component supports communication between the client and cameras. Specific downstream consequences, including code execution or data disclosure, are not established by the available information.
Mitigation
If you can’t patch tonight, do this now.
Restrict network access to the FreeSWITCH Event Socket interface to trusted systems. For American Dynamics victor versions earlier than 5.7.1, disable the SIP feature until the upgrade can be applied.
Remediation
Patch, then assume compromise.
Replace the FreeSWITCH Event Socket default password with a strong, unique secret and update dependent integrations accordingly. For American Dynamics victor, upgrade to version 5.7.1, which addresses the hard-coded-password issue. A specific fixed FreeSWITCH release is not identified.
Exploits
3 exploits validated by Mallory's analysis.
Affected products & vendors
Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.
Frequently asked questions
- Is CVE-2019-19492 exploited in the wild?
- As of Nov 19, 2026, Mallory has no reports of CVE-2019-19492 being exploited in the wild. It is not listed in CISA KEV.
- Is there a public exploit for CVE-2019-19492?
- Yes. Mallory tracks 3 public exploits or proofs of concept for CVE-2019-19492, the earliest disclosed Nov 3, 2019.
- Is there a patch for CVE-2019-19492?
- Replace the FreeSWITCH Event Socket default password with a strong, unique secret and update dependent integrations accordingly. For American Dynamics victor, upgrade to version 5.7.1, which addresses the hard-coded-password issue.
- What products are affected by CVE-2019-19492?
- Freeswitch.
- How severe is CVE-2019-19492?
- CVE-2019-19492 has a CVSS v3.1 score of 9.8 (Critical) and an EPSS score of 64.9% (99th percentile) as of Nov 19, 2026.
Recent activity
6 sources tracked across advisories, community write-ups, and news. New activity surfaces here as Mallory finds it.