CVE-2019-7666: Improper Authentication in Prima Systems FlexAir <=2.3.38
- Vendor
- Primasystems
Prima Systems FlexAir versions 2.3.38 and prior are vulnerable to improper authentication. The application uses the MD5 hash of the password for authentication, allowing an attacker with access to the database to authenticate as an admin without needing to decrypt or know the original password.
Impact, mitigation & remediation
What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.
Impact
What an attacker gets, and what they’ve been doing with it.
An attacker with access to the application's database can authenticate as an admin user by using the stored MD5 hash, bypassing the need to know or crack the original password. This can lead to full administrative compromise of the FlexAir system.
Mitigation
If you can’t patch tonight, do this now.
Restrict access to the database to trusted users only. Monitor for unauthorized access to the database. Consider implementing additional authentication controls, such as multi-factor authentication, until the vulnerability is remediated.
Remediation
Patch, then assume compromise.
Upgrade to a version of FlexAir that implements secure password handling and authentication mechanisms, such as using salted hashes and proper password verification routines. Do not rely on MD5 hashes for authentication.
Exploits
No validated public exploits yet. Hidden: 1 not yet analyzed, such as Exploit-DB entries.
Affected products & vendors
Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.
References
Frequently asked questions
- Is CVE-2019-7666 exploited in the wild?
- As of Oct 16, 2026, Mallory has no reports of CVE-2019-7666 being exploited in the wild. It is not listed in CISA KEV.
- Is there a public exploit for CVE-2019-7666?
- Yes. As of Oct 16, 2026, Mallory has reports of a public exploit for CVE-2019-7666.
- Is there a patch for CVE-2019-7666?
- Upgrade to a version of FlexAir that implements secure password handling and authentication mechanisms, such as using salted hashes and proper password verification routines. Do not rely on MD5 hashes for authentication.
- What products are affected by CVE-2019-7666?
- Primasystems Flexair.
- How severe is CVE-2019-7666?
- CVE-2019-7666 has a CVSS v3.1 score of 8.8 (High) and an EPSS score of 14.6% (97th percentile) as of Oct 16, 2026.