CVE-2020-11963: RCE via Bash metacharacter injection in IQrouter web panel (unconfigured state)
- Vendor
- Evenroute
CVE-2020-11963 affects IQrouter through 3.3.1. In the device’s unconfigured (initial setup) state, the web-panel contains multiple remote code execution issues caused by Bash shell metacharacter injection, allowing attacker-controlled input to be interpreted by a shell and executed as commands. The vendor disputes practical exploitability by asserting that the forced initial configuration requires setting a secure password, and therefore the vulnerable unconfigured state should not persist in normal deployments; however, the CVE description indicates the condition exists for unconfigured releases.
Impact, mitigation & remediation
What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.
Impact
What an attacker gets, and what they’ve been doing with it.
Remote code execution on the IQrouter device via the web management interface when the device is in an unconfigured/initial setup state, potentially enabling full compromise of the router (e.g., arbitrary command execution with the privileges of the web-panel’s execution context).
Mitigation
If you can’t patch tonight, do this now.
Do not expose the IQrouter web-panel to untrusted networks during initial provisioning. Complete initial configuration promptly (including setting a secure password) before connecting the device to hostile networks. Where possible, restrict management access (e.g., LAN-only, firewall rules) during setup to reduce the window in which the unconfigured state is reachable.
Remediation
Patch, then assume compromise.
Upgrade IQrouter to a version that removes the shell metacharacter injection conditions in the web-panel initial setup flow (post-3.3.1, per vendor fixes if available). Ensure the device is fully configured immediately upon deployment, including setting a strong administrative password as required by the initial configuration process.
Exploits
No public exploits tracked yet. Mallory keeps watching.
Affected products & vendors
Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.
References
Frequently asked questions
- Is CVE-2020-11963 exploited in the wild?
- Yes. As of Oct 16, 2026, Mallory has reports of exploitation in the wild.
- Is there a public exploit for CVE-2020-11963?
- As of Oct 16, 2026, Mallory has found no public exploit for CVE-2020-11963.
- Is there a patch for CVE-2020-11963?
- Upgrade IQrouter to a version that removes the shell metacharacter injection conditions in the web-panel initial setup flow (post-3.3.1, per vendor fixes if available). Ensure the device is fully configured immediately upon deployment, including setting a strong administrative password as required by the initial configuration process.
- What products are affected by CVE-2020-11963?
- Evenroute Iqrouter Firmware.
- How severe is CVE-2020-11963?
- CVE-2020-11963 has a CVSS v3.1 score of 9.8 (Critical) and an EPSS score of 3.2% (88th percentile) as of Oct 16, 2026.
Recent activity
2 sources tracked across advisories and community write-ups. News coverage will land here when it surfaces.
No news coverage yet. Advisories and community discussion only.