CVE-2021-28150: Sensitive File Disclosure in Hongdian H8922 /backup2.cgi
- Vendor
- Hongdian
Hongdian H8922 version 3.0.5 contains an information disclosure vulnerability in the /backup2.cgi endpoint. An unprivileged guest user can access and read cli.conf, a configuration file containing the administrator password and other sensitive device data. The issue stems from insufficient access control on the backup/export functionality, allowing a low-privileged account to retrieve sensitive configuration material that should be restricted to administrators.
Impact, mitigation & remediation
What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.
Impact
What an attacker gets, and what they’ve been doing with it.
Successful exploitation allows disclosure of highly sensitive configuration data, including the administrator password and other information stored in cli.conf. This can enable compromise of the administrative account, unauthorized device reconfiguration, further access to connected infrastructure, and follow-on attacks using exposed credentials or network settings.
Mitigation
If you can’t patch tonight, do this now.
Limit management interface exposure to trusted networks only, enforce network-layer access controls to the web administration interface, and prevent guest or low-privileged accounts from accessing backup/export functionality. Monitor for requests to /backup2.cgi and audit device access logs for unauthorized retrieval of configuration data. As a compensating control, change all potentially exposed credentials and segregate affected devices from untrusted users until remediation is applied.
Remediation
Patch, then assume compromise.
Upgrade to a vendor-provided fixed version if available. If no patched firmware is available, restrict access to the vulnerable management interface and specifically disable or block access to /backup2.cgi for non-administrative users. Review and rotate any credentials stored in cli.conf, especially the administrator password, because they should be considered exposed if vulnerable systems were accessible to guest users.
Exploits
No public exploits tracked yet. Mallory keeps watching.
Affected products & vendors
Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.
Frequently asked questions
- Is CVE-2021-28150 exploited in the wild?
- Yes. As of Oct 16, 2026, Mallory has reports of exploitation in the wild.
- Is there a public exploit for CVE-2021-28150?
- Yes. As of Oct 16, 2026, Mallory has reports of a public exploit for CVE-2021-28150.
- Is there a patch for CVE-2021-28150?
- Upgrade to a vendor-provided fixed version if available. If no patched firmware is available, restrict access to the vulnerable management interface and specifically disable or block access to /backup2.cgi for non-administrative users.
- What products are affected by CVE-2021-28150?
- Hongdian H8922 Firmware.
- How severe is CVE-2021-28150?
- CVE-2021-28150 has a CVSS v3.1 score of 5.5 (Medium) and an EPSS score of 2.7% (86th percentile) as of Oct 16, 2026.
Recent activity
2 sources tracked across advisories and community write-ups. News coverage will land here when it surfaces.
No news coverage yet. Advisories and community discussion only.