Skip to main content
Mallory
CriticalPublic exploitVulnerability

CVE-2022-35555: Command injection in Tenda W6 exeCommand

Published Aug 11, 2022 · Updated 1 month ago
Trending this weekNot trendingOutside this week’s top 100
Mention activity · 30 daysNo mention activity in the last 30 days.
CVSS9.8Critical · v3.1
EPSS39.7%99th percentile
CISA KEVNoNot listed
In the wildReported2 exploitation records in Mallory
Vendor
Tenda
IdentifiersCVE-2022-35555CWE-78 · Improper Neutralization of Special…

CVE-2022-35555 is a command injection vulnerability in the exeCommand handler of Tenda W6 firmware V1.0.0.9(4122). Attackers can supply crafted cmdinput parameters to execute arbitrary operating-system commands. The vulnerability has been targeted as an initial-access entry point in the ClingSTUN malware campaign.

Do you run this?See affected versions in your environment and whether adversaries are exploiting this vulnerability against assets like yours.
Check your exposure
Analyst brief

Impact, mitigation & remediation

What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.

Impact

What an attacker gets, and what they’ve been doing with it.

Successful exploitation permits arbitrary command execution on the affected device. The execution privilege level is not established. Exploitation can support malware deployment; the ClingSTUN campaign targeted this vulnerability among its entry points for compromising devices and converting them into persistent, remotely controlled proxy nodes.

Mitigation

If you can’t patch tonight, do this now.

Restrict access to the affected management service and disable unnecessary Internet-facing services. Isolate vulnerable devices when an update cannot be applied, particularly unsupported equipment. Monitor for suspicious processes, persistence changes, and unexpected UDP or recurring STUN activity associated with ClingSTUN infections.

Remediation

Patch, then assume compromise.

Apply an available vendor firmware update that addresses CVE-2022-35555. A specific fixed firmware version is not identified. Replace affected devices that no longer receive security updates.

Public exploits

Exploits

No public exploits tracked yet. Mallory keeps watching.

View more in app →
No public exploit code observed for this vulnerability. Mallory keeps watching.
Exposure surface

Affected products & vendors

Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.

VendorProductType
TendaW6 Firmwareoperating_system
FAQ

Frequently asked questions

Is CVE-2022-35555 exploited in the wild?
Yes. As of Oct 16, 2026, Mallory has reports of exploitation in the wild.
Is there a public exploit for CVE-2022-35555?
Yes. As of Oct 16, 2026, Mallory has reports of a public exploit for CVE-2022-35555.
Is there a patch for CVE-2022-35555?
Apply an available vendor firmware update that addresses CVE-2022-35555. A specific fixed firmware version is not identified.
What products are affected by CVE-2022-35555?
Tenda W6 Firmware.
How severe is CVE-2022-35555?
CVE-2022-35555 has a CVSS v3.1 score of 9.8 (Critical) and an EPSS score of 39.7% (99th percentile) as of Oct 16, 2026.
Mallory platform

The version that knows your environment.

This page is what’s public. Mallory adds the parts that aren’t: which of your assets are affected, which adversaries are exploiting it right now, and which detections to deploy tonight.
Exposure mappingQuery your assets running an affected version, and investigate the blast radius.
Threat actor evidenceEvery report linking this CVE to a named adversary.
Associated malware2Malware families linked to this CVE, with evidence and IOCs.
Detection signaturesYARA, Sigma, Snort, and vendor rules, auto-deployed to your SIEM.
Vendor-by-vendor mappingCross-references every affected SKU, including bundled OEM variants.
Social activityCommunity discussion across Reddit, Mastodon, and other social sources.