Skip to main content
Mallory
HighPublic exploitVulnerability

CVE-2022-40005: Command Injection in Intelbras WiFiber 120AC inMesh

Published Dec 25, 2022 · Updated 1 month ago
Trending this weekNot trendingOutside this week’s top 100
Mention activity · 30 daysNo mention activity in the last 30 days.
CVSS8.8High · v3.1
EPSS35.0%98th percentile
CISA KEVNoNot listed
In the wildReported3 exploitation records in Mallory
Vendor
Intelbras
IdentifiersCVE-2022-40005CWE-78 · Improper Neutralization of Special…

CVE-2022-40005 is a command injection vulnerability affecting Intelbras WiFiber 120AC inMesh devices before version 1-1-220826. Authenticated users can inject operating system commands through diagnostic functionality exposed by the /boaform/formPing6 and /boaform/formTracert endpoints, which are used for ping and traceroute operations. The flaw arises from insufficient neutralization of user-controlled input before it is passed to system-level command execution, enabling an attacker with valid access to execute arbitrary commands on the device.

Do you run this?See affected versions in your environment and whether adversaries are exploiting this vulnerability against assets like yours.
Check your exposure
Analyst brief

Impact, mitigation & remediation

What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.

Impact

What an attacker gets, and what they’ve been doing with it.

Successful exploitation allows an authenticated attacker to execute arbitrary operating system commands on the affected device. This can result in full compromise of the device, including unauthorized administrative actions, modification of configuration, deployment of malware, use of the device in botnet activity, persistence, and disruption of network services provided by the router.

Mitigation

If you can’t patch tonight, do this now.

Restrict access to the device management interface to trusted administrative networks only, disable or limit exposure of diagnostic features such as ping and traceroute where possible, enforce strong unique credentials for all administrative accounts, and monitor for unexpected command execution or configuration changes on affected devices. Until patched, avoid exposing the management interface to untrusted networks.

Remediation

Patch, then assume compromise.

Upgrade Intelbras WiFiber 120AC inMesh devices to version 1-1-220826 or later, as versions before 1-1-220826 are affected. If vendor-fixed firmware is available beyond that release, deploy the latest supported version across all affected devices and verify that the update has been successfully applied.

Public exploits

Exploits

No public exploits tracked yet. Mallory keeps watching.

View more in app →
No public exploit code observed for this vulnerability. Mallory keeps watching.
Exposure surface

Affected products & vendors

Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.

VendorProductType
IntelbrasWifiber 120ac Inmesh Firmwareoperating_system
FAQ

Frequently asked questions

Is CVE-2022-40005 exploited in the wild?
Yes. As of Oct 16, 2026, Mallory has reports of exploitation in the wild.
Is there a public exploit for CVE-2022-40005?
Yes. As of Oct 16, 2026, Mallory has reports of a public exploit for CVE-2022-40005.
Is there a patch for CVE-2022-40005?
Upgrade Intelbras WiFiber 120AC inMesh devices to version 1-1-220826 or later, as versions before 1-1-220826 are affected. If vendor-fixed firmware is available beyond that release, deploy the latest supported version across all affected devices and verify that the update has been successfully applied.
What products are affected by CVE-2022-40005?
Intelbras Wifiber 120ac Inmesh Firmware.
How severe is CVE-2022-40005?
CVE-2022-40005 has a CVSS v3.1 score of 8.8 (High) and an EPSS score of 35.0% (98th percentile) as of Oct 16, 2026.
Mallory platform

The version that knows your environment.

This page is what’s public. Mallory adds the parts that aren’t: which of your assets are affected, which adversaries are exploiting it right now, and which detections to deploy tonight.
Exposure mappingQuery your assets running an affected version, and investigate the blast radius.
Threat actor evidenceEvery report linking this CVE to a named adversary.
Associated malware3Malware families linked to this CVE, with evidence and IOCs.
Detection signaturesYARA, Sigma, Snort, and vendor rules, auto-deployed to your SIEM.
Vendor-by-vendor mappingCross-references every affected SKU, including bundled OEM variants.
Social activityCommunity discussion across Reddit, Mastodon, and other social sources.