Skip to main content
Mallory
HighPublic exploitVulnerability

CVE-2024-45890: Authenticated command injection in DrayTek Vigor3900

Published Nov 4, 2024 · Updated 1 month ago
Trending this weekNot trendingOutside this week’s top 100
Mention activity · 30 daysNo mention activity in the last 30 days.
CVSS8.0High · v3.1
EPSS2.1%83rd percentile
CISA KEVNoNot listed
In the wildReported2 exploitation records in Mallory
Vendor
Draytek
IdentifiersCVE-2024-45890CWE-78 · Improper Neutralization of Special…

CVE-2024-45890 is a post-authentication command-injection vulnerability in DrayTek Vigor3900 firmware version 1.5.1.3. The flaw occurs in a CGI action handler when the action parameter is set to download_ovpn. Exploitation allows an authenticated attacker to inject operating-system commands on the affected device. The vulnerability has been associated with the Gayfemboy botnet campaign.

Do you run this?See affected versions in your environment and whether adversaries are exploiting this vulnerability against assets like yours.
Check your exposure
Analyst brief

Impact, mitigation & remediation

What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.

Impact

What an attacker gets, and what they’ve been doing with it.

Successful exploitation enables command execution on the affected router. The execution privilege level and specific confidentiality or availability effects are not established. Exploitation has been associated with Gayfemboy activity, which compromises network devices for botnet operations.

Mitigation

If you can’t patch tonight, do this now.

Deploy IPS coverage for CVE-2024-45890. Eliminate default or weak administrative passwords and enable MFA where supported. Segment network devices and restrict east-west and egress traffic to reduce exposure and post-compromise activity.

Remediation

Patch, then assume compromise.

Apply vendor firmware updates that address CVE-2024-45890. A specific fixed firmware version is not identified in the available information.

Public exploits

Exploits

No public exploits tracked yet. Mallory keeps watching.

View more in app →
No public exploit code observed for this vulnerability. Mallory keeps watching.
Exposure surface

Affected products & vendors

Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.

VendorProductType
DraytekVigor3900 Firmwareoperating_system
FAQ

Frequently asked questions

Is CVE-2024-45890 exploited in the wild?
Yes. As of Oct 10, 2026, Mallory has reports of exploitation in the wild.
Is there a public exploit for CVE-2024-45890?
Yes. As of Oct 10, 2026, Mallory has reports of a public exploit for CVE-2024-45890.
Is there a patch for CVE-2024-45890?
Apply vendor firmware updates that address CVE-2024-45890. A specific fixed firmware version is not identified in the available information.
What products are affected by CVE-2024-45890?
Draytek Vigor3900 Firmware.
How severe is CVE-2024-45890?
CVE-2024-45890 has a CVSS v3.1 score of 8.0 (High) and an EPSS score of 2.1% (83rd percentile) as of Oct 10, 2026.
Mallory platform

The version that knows your environment.

This page is what’s public. Mallory adds the parts that aren’t: which of your assets are affected, which adversaries are exploiting it right now, and which detections to deploy tonight.
Exposure mappingQuery your assets running an affected version, and investigate the blast radius.
Threat actor evidenceEvery report linking this CVE to a named adversary.
Associated malware2Malware families linked to this CVE, with evidence and IOCs.
Detection signaturesYARA, Sigma, Snort, and vendor rules, auto-deployed to your SIEM.
Vendor-by-vendor mappingCross-references every affected SKU, including bundled OEM variants.
Social activity2Community discussion across Reddit, Mastodon, and other social sources.