CVE-2024-7029: Unauthenticated command injection in AVTECH AVM1203 cameras
- Vendor
- Avtech
CVE-2024-7029 is a command-injection vulnerability in the brightness functionality of AVTECH IP cameras. Attacker-controlled input to the brightness argument associated with the action parameter permits network-delivered commands to execute without authentication, with the privileges of the running process owner. Confirmed affected devices are AVTECH AVM1203 cameras running firmware FullImg-1023-1007-1011-1009 and earlier. Other AVTECH cameras and network video recorders may also be affected, but additional models are not confirmed. The vulnerability has been exploited to deploy Mirai variants and ClingSTUN.
Impact, mitigation & remediation
What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.
Impact
What an attacker gets, and what they’ve been doing with it.
Successful exploitation enables remote command execution and malware deployment on affected cameras with the permissions of the vulnerable process. Observed abuse includes device compromise and enrollment in Mirai botnets, including Corona and Murdoc, as well as deployment of the ClingSTUN backdoor. Subsequent malware can provide persistent remote access, proxy functionality, or participation in DDoS operations. Some advisories describe elevated execution privileges, but the precise process identity is not established.
Mitigation
If you can’t patch tonight, do this now.
Remove direct internet exposure, restrict access to camera management services, and isolate affected devices behind firewalls from business and critical networks. If remote access is necessary, use maintained, securely configured VPN access. Take vulnerable cameras out of service where feasible, and monitor for exploitation attempts, suspicious processes, startup changes, and unusual network activity. Assess operational impacts before implementing defensive changes.
Remediation
Patch, then assume compromise.
Decommission or replace affected AVM1203 cameras when remediation is unavailable. No specific fixed firmware version for affected legacy units is identified. Contact AVTECH regarding available updates or replacement options and apply applicable vendor security updates when available. AVTECH stated that currently marketed models had addressed the issue and that it was evaluating an update or replacement service for discontinued affected units; this does not establish a released fix for legacy AVM1203 cameras.
Exploits
3 exploits validated by Mallory's analysis.
Affected products & vendors
Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.
References
Frequently asked questions
- Is CVE-2024-7029 exploited in the wild?
- Yes. As of Oct 9, 2026, Mallory has reports of exploitation in the wild.
- Is there a public exploit for CVE-2024-7029?
- Yes. Mallory tracks 3 public exploits or proofs of concept for CVE-2024-7029, the earliest disclosed Aug 30, 2024.
- Is there a patch for CVE-2024-7029?
- Decommission or replace affected AVM1203 cameras when remediation is unavailable. No specific fixed firmware version for affected legacy units is identified.
- What products are affected by CVE-2024-7029?
- Avtech Avm1203 Firmware.
- How severe is CVE-2024-7029?
- CVE-2024-7029 has a CVSS v4 score of 8.7 (High) and an EPSS score of 43.3% (99th percentile) as of Oct 9, 2026.
Recent activity
18 sources tracked across advisories, community write-ups, and news. New activity surfaces here as Mallory finds it.