Skip to main content
Mallory
MediumPublic exploitVulnerability

CVE-2024-7214: Command Injection in TOTOLINK LR350 setWanCfg

Published Jul 30, 2024 · Updated 1 month ago
Trending this weekNot trendingOutside this week’s top 100
Mention activity · 30 daysNo mention activity in the last 30 days.
CVSS5.3Medium · v4
EPSS5.5%94th percentile
CISA KEVNoNot listed
In the wildReported1 exploitation record in Mallory
Vendor
Totolink
IdentifiersCVE-2024-7214CWE-77 · Improper Neutralization of Special…

CVE-2024-7214 is a command injection vulnerability in the setWanCfg function of /cgi-bin/cstecgi.cgi in TOTOLINK LR350 firmware version 9.3.5u.6369_B20220309. The vulnerability is triggered by improper sanitization of the hostName argument, allowing remote attackers to inject and execute arbitrary system commands on the device.

Do you run this?See affected versions in your environment and whether adversaries are exploiting this vulnerability against assets like yours.
Check your exposure
Analyst brief

Impact, mitigation & remediation

What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.

Impact

What an attacker gets, and what they’ve been doing with it.

Successful exploitation allows remote attackers to execute arbitrary commands on the affected TOTOLINK LR350 device with the privileges of the web server process, potentially leading to full device compromise, lateral movement, or use in botnets. The exploit is publicly available, increasing the risk of widespread exploitation.

Mitigation

If you can’t patch tonight, do this now.

Restrict network access to the device, especially from untrusted sources. Employ network segmentation and firewall rules to limit exposure. Disable remote management interfaces if not required. Monitor for signs of compromise and consider using intrusion detection systems to detect exploitation attempts.

Remediation

Patch, then assume compromise.

No official patch or vendor response is available as of this writing. Users should consider replacing the device or isolating it from untrusted networks. Monitor the vendor's website for any future updates or advisories.

Public exploits

Exploits

No public exploits tracked yet. Mallory keeps watching.

View more in app →
No public exploit code observed for this vulnerability. Mallory keeps watching.
Exposure surface

Affected products & vendors

Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.

VendorProductType
TotolinkLr350hardware
TotolinkLr350 Firmwareapplication
FAQ

Frequently asked questions

Is CVE-2024-7214 exploited in the wild?
Yes. As of Oct 16, 2026, Mallory has reports of exploitation in the wild.
Is there a public exploit for CVE-2024-7214?
Yes. As of Oct 16, 2026, Mallory has reports of a public exploit for CVE-2024-7214.
Is there a patch for CVE-2024-7214?
No official patch or vendor response is available as of this writing. Users should consider replacing the device or isolating it from untrusted networks.
What products are affected by CVE-2024-7214?
Totolink Lr350 and Totolink Lr350 Firmware.
How severe is CVE-2024-7214?
CVE-2024-7214 has a CVSS v4 score of 5.3 (Medium) and an EPSS score of 5.5% (94th percentile) as of Oct 16, 2026.
Mallory platform

The version that knows your environment.

This page is what’s public. Mallory adds the parts that aren’t: which of your assets are affected, which adversaries are exploiting it right now, and which detections to deploy tonight.
Exposure mappingQuery your assets running an affected version, and investigate the blast radius.
Threat actor evidenceEvery report linking this CVE to a named adversary.
Associated malware2Malware families linked to this CVE, with evidence and IOCs.
Detection signaturesYARA, Sigma, Snort, and vendor rules, auto-deployed to your SIEM.
Vendor-by-vendor mappingCross-references every affected SKU, including bundled OEM variants.
Social activityCommunity discussion across Reddit, Mastodon, and other social sources.