CVE-2024-8957: OS Command Injection in PTZOptics PT30X-SDI/NDI Cameras
- Vendor
- Ptzoptics
CVE-2024-8957 is an OS command injection vulnerability affecting PTZOptics PT30X-SDI/NDI-xx cameras running firmware earlier than 6.3.40. Insufficient validation of the ntp_addr configuration value allows injected OS commands to execute when the NTP client starts. Standalone exploitation requires high privileges, but chaining the vulnerability with CVE-2024-8956 enables remote, unauthenticated command execution. The vulnerability has been exploited in the wild, including by the Gayfemboy botnet.
Impact, mitigation & remediation
What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.
Impact
What an attacker gets, and what they’ve been doing with it.
Successful exploitation can compromise device confidentiality, integrity, and availability through arbitrary OS command execution. Potential consequences include camera takeover, access to sensitive information, modification of camera settings, malware deployment, disruption of video feeds, and use of the camera as a pivot to other network devices.
Mitigation
If you can’t patch tonight, do this now.
If immediate patching is not possible, restrict access to device management interfaces and prevent untrusted parties from modifying camera configuration values such as ntp_addr. Limit network reachability to trusted administrative hosts, isolate affected cameras from internet exposure, and monitor for unexpected process execution or configuration changes associated with ntp_client startup. Because the context states remote unauthenticated exploitation is possible when chained with CVE-2024-8956, mitigation should also include addressing that companion vulnerability and reducing exposure of any vulnerable management functionality.
Remediation
Patch, then assume compromise.
Upgrade affected PTZOptics PT30X-SDI/NDI-xx cameras to vendor firmware version 6.3.40 or later, which addresses this vulnerability.
Exploits
No public exploits tracked yet. Mallory keeps watching.
Affected products & vendors
Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.
References
Frequently asked questions
- Is CVE-2024-8957 exploited in the wild?
- Yes. As of Nov 14, 2026, Mallory has reports of exploitation in the wild, and CISA added it to KEV on Nov 4, 2024.
- Is there a public exploit for CVE-2024-8957?
- Yes. As of Nov 14, 2026, Mallory has reports of a public exploit for CVE-2024-8957.
- Is there a patch for CVE-2024-8957?
- Upgrade affected PTZOptics PT30X-SDI/NDI-xx cameras to vendor firmware version 6.3.40 or later, which addresses this vulnerability.
- What products are affected by CVE-2024-8957?
- Ptzoptics Pt30x-Sdi, Ptzoptics Pt30x-Ndi Firmware, Ptzoptics Pt30x-Ndi-Xx-G2, Ptzoptics Pt30x-Ndi-Xx-G2 Firmware, and Ptzoptics Pt30x-Sdi Firmware.
- How severe is CVE-2024-8957?
- CVE-2024-8957 has a CVSS v3.1 score of 7.2 (High) and an EPSS score of 79.8% (100th percentile) as of Nov 14, 2026.
Recent activity
6 sources tracked across advisories, community write-ups, and news. New activity surfaces here as Mallory finds it.