Skip to main content
Mallory
HighVulnerability

CVE-2025-14272: Improper Authorization in Rockwell Automation FactoryTalk Analytics PavilionX API Endpoints

Published Jun 16, 2026 · Updated 2 months ago
Trending this weekNot trendingOutside this week’s top 100
Mention activity · 30 daysNo mention activity in the last 30 days.
CVSS8.3High · v4
EPSS0.31%17th percentile
CISA KEVNoNot listed
In the wildNoneNo exploitation reported
IdentifiersCVE-2025-14272CWE-862 · Missing Authorization

CVE-2025-14272 is an improper authorization vulnerability in Pavilion, affecting Rockwell Automation FactoryTalk Analytics PavilionX versions earlier than 7.01. The issue is caused by improper authorization enforcement in API endpoints, allowing requests to reach privileged functionality without adequate authorization checks. According to the advisory content, successful exploitation can let an unauthorized actor execute privileged operations through the API, including user management, role management, and other administrative actions.

Do you run this?See affected versions in your environment and whether adversaries are exploiting this vulnerability against assets like yours.
Check your exposure
Analyst brief

Impact, mitigation & remediation

What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.

Impact

What an attacker gets, and what they’ve been doing with it.

Successful exploitation allows an unauthorized attacker to perform privileged administrative operations in the affected PavilionX deployment. Reported impacts include unauthorized user management, role management, and other administrative actions. The published CVSS information indicates network-based exploitation with no privileges and no user interaction required, with potential for high confidentiality impact and limited integrity and availability impact.

Mitigation

If you can’t patch tonight, do this now.

If immediate upgrade is not possible, minimize exposure of affected control system devices and ensure they are not directly accessible from the internet. Place control system networks and remote devices behind firewalls and isolate them from business networks. Where remote access is required, use secure remote-access solutions such as VPNs and keep those VPNs fully updated. Apply defense-in-depth measures and perform impact analysis and risk assessment before deploying changes in ICS environments.

Remediation

Patch, then assume compromise.

Upgrade Rockwell Automation FactoryTalk Analytics PavilionX to version 7.01 or later. Refer to Rockwell Automation advisory SD1777 for vendor-specific remediation guidance.

Public exploits

Exploits

No public exploits tracked yet. Mallory keeps watching.

View more in app →
No public exploit code observed for this vulnerability. Mallory keeps watching.
FAQ

Frequently asked questions

Is CVE-2025-14272 exploited in the wild?
As of Sep 25, 2026, Mallory has no reports of CVE-2025-14272 being exploited in the wild. It is not listed in CISA KEV.
Is there a public exploit for CVE-2025-14272?
As of Sep 25, 2026, Mallory has found no public exploit for CVE-2025-14272.
Is there a patch for CVE-2025-14272?
Upgrade Rockwell Automation FactoryTalk Analytics PavilionX to version 7.01 or later. Refer to Rockwell Automation advisory SD1777 for vendor-specific remediation guidance.
How severe is CVE-2025-14272?
CVE-2025-14272 has a CVSS v4 score of 8.3 (High) and an EPSS score of 0.31% (17th percentile) as of Sep 25, 2026.
Activity feed

Recent activity

5 sources tracked across advisories, community write-ups, and news. New activity surfaces here as Mallory finds it.

View more in app →
Do you run this?See affected versions in your environment and whether adversaries are exploiting this vulnerability against assets like yours.
Check your exposure
Mallory platform

The version that knows your environment.

This page is what’s public. Mallory adds the parts that aren’t: which of your assets are affected, which adversaries are exploiting it right now, and which detections to deploy tonight.
Exposure mappingQuery your assets running an affected version, and investigate the blast radius.
Threat actor evidenceEvery report linking this CVE to a named adversary.
Associated malwareMalware families linked to this CVE, with evidence and IOCs.
Detection signaturesYARA, Sigma, Snort, and vendor rules, auto-deployed to your SIEM.
Vendor-by-vendor mappingCross-references every affected SKU, including bundled OEM variants.
Social activity2Community discussion across Reddit, Mastodon, and other social sources.