CVE-2025-23397: Memory Corruption in Siemens Teamcenter Visualization and Tecnomatix Plant Simulation WRL File Parser
- Vendor
- Siemens
CVE-2025-23397 is a memory corruption vulnerability in Siemens Teamcenter Visualization (versions prior to V14.3.0.13, V2312.0009, V2406.0007, V2412.0002) and Tecnomatix Plant Simulation (versions prior to V2302.0021, V2404.0010). The vulnerability exists in the WRL file parser, where specially crafted WRL files can trigger memory corruption, potentially leading to arbitrary code execution within the context of the current process.
Impact, mitigation & remediation
What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.
Impact
What an attacker gets, and what they’ve been doing with it.
Successful exploitation allows an attacker to execute arbitrary code with the privileges of the user running the affected application. This could lead to full compromise of the system if the application is run with high privileges, and may be leveraged for further lateral movement or data exfiltration.
Mitigation
If you can’t patch tonight, do this now.
Do not open untrusted or suspicious WRL files with the affected applications. Restrict access to the applications and ensure that users operate with the least privileges necessary. Employ endpoint protection solutions to detect and block exploitation attempts.
Remediation
Patch, then assume compromise.
Upgrade Teamcenter Visualization to V14.3.0.13, V2312.0009, V2406.0007, or V2412.0002 (as applicable), and Tecnomatix Plant Simulation to V2302.0021 or V2404.0010. These versions contain fixes for the memory corruption vulnerability in the WRL file parser.
Exploits
No public exploits tracked yet. Mallory keeps watching.
Affected products & vendors
Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.
Frequently asked questions
- Is CVE-2025-23397 exploited in the wild?
- Yes. As of Sep 25, 2026, Mallory has reports of exploitation in the wild.
- Is there a public exploit for CVE-2025-23397?
- As of Sep 25, 2026, Mallory has found no public exploit for CVE-2025-23397.
- Is there a patch for CVE-2025-23397?
- Upgrade Teamcenter Visualization to V14.3.0.13, V2312.0009, V2406.0007, or V2412.0002 (as applicable), and Tecnomatix Plant Simulation to V2302.0021 or V2404.0010. These versions contain fixes for the memory corruption vulnerability in the WRL file parser.
- What products are affected by CVE-2025-23397?
- Siemens Teamcenter Visualization and Siemens Tecnomatix Plant Simulation.
- How severe is CVE-2025-23397?
- CVE-2025-23397 has a CVSS v4 score of 7.3 (High) and an EPSS score of 0.17% (6th percentile) as of Sep 25, 2026.