Skip to main content
Mallory
HighVulnerability

CVE-2025-40817: Unauthenticated Time Modification in Siemens LOGO! and SIPLUS LOGO! V8.4 BM

Published Nov 11, 2025 · Updated 1 month ago
Trending this weekNot trendingOutside this week’s top 100
Mention activity · 30 daysNo mention activity in the last 30 days.
CVSS7.1High · v4
EPSS0.36%22nd percentile
CISA KEVNoNot listed
In the wildNoneNo exploitation reported
IdentifiersCVE-2025-40817CWE-306 · Missing Authentication for…

CVE-2025-40817 is a missing-authentication vulnerability affecting Siemens LOGO! V8.4 BM and SIPLUS LOGO! V8.4 BM devices running firmware earlier than V1.84.05. Affected variants include 12/24RCE, 12/24RCEo, 230RCE, 230RCEo, 24CE, 24CEo, 24RCE, and 24RCEo. Insufficient validation of device interactions allows an unauthenticated attacker with adjacent-network access to modify the device time, potentially altering device behavior.

Do you run this?See affected versions in your environment and whether adversaries are exploiting this vulnerability against assets like yours.
Check your exposure
Analyst brief

Impact, mitigation & remediation

What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.

Impact

What an attacker gets, and what they’ve been doing with it.

Unauthorized modification of the device clock compromises time-setting integrity and can alter device behavior. The specific operational consequences depend on how the device uses time in its configured functions. Arbitrary code execution and IP address modification are separate vulnerabilities and are not established impacts of CVE-2025-40817.

Mitigation

If you can’t patch tonight, do this now.

Restrict access to UDP port 10006 to trusted IP addresses. Apply appropriate network access controls and configure the operating environment according to Siemens Industrial Security operational guidelines and product manuals.

Remediation

Patch, then assume compromise.

Update affected LOGO! V8.4 BM and SIPLUS LOGO! V8.4 BM devices to firmware V1.84.05 or later using the Siemens-provided firmware update.

Public exploits

Exploits

No public exploits tracked yet. Mallory keeps watching.

View more in app →
No public exploit code observed for this vulnerability. Mallory keeps watching.
FAQ

Frequently asked questions

Is CVE-2025-40817 exploited in the wild?
As of Oct 25, 2026, Mallory has no reports of CVE-2025-40817 being exploited in the wild. It is not listed in CISA KEV.
Is there a public exploit for CVE-2025-40817?
As of Oct 25, 2026, Mallory has found no public exploit for CVE-2025-40817.
Is there a patch for CVE-2025-40817?
Update affected LOGO! V8.4 BM and SIPLUS LOGO!
How severe is CVE-2025-40817?
CVE-2025-40817 has a CVSS v4 score of 7.1 (High) and an EPSS score of 0.36% (22nd percentile) as of Oct 25, 2026.
Activity feed

Recent activity

5 sources tracked across advisories and community write-ups. News coverage will land here when it surfaces.

View more in app →

No news coverage yet. Advisories and community discussion only.

Do you run this?See affected versions in your environment and whether adversaries are exploiting this vulnerability against assets like yours.
Check your exposure
Mallory platform

The version that knows your environment.

This page is what’s public. Mallory adds the parts that aren’t: which of your assets are affected, which adversaries are exploiting it right now, and which detections to deploy tonight.
Exposure mappingQuery your assets running an affected version, and investigate the blast radius.
Threat actor evidenceEvery report linking this CVE to a named adversary.
Associated malwareMalware families linked to this CVE, with evidence and IOCs.
Detection signaturesYARA, Sigma, Snort, and vendor rules, auto-deployed to your SIEM.
Vendor-by-vendor mappingCross-references every affected SKU, including bundled OEM variants.
Social activity3Community discussion across Reddit, Mastodon, and other social sources.