Skip to main content
Mallory
LowPublic exploitVulnerability

CVE-2025-7081: OS Command Injection in Belkin F9K1122 formSetWanStatic

Published Jul 6, 2025 · Updated 2 months ago
Trending this weekNot trendingOutside this week’s top 100
Mention activity · 30 daysNo mention activity in the last 30 days.
CVSS2.1Low · v4
EPSS20.4%98th percentile
CISA KEVNoNot listed
In the wildReported11 exploitation records in Mallory
Vendor
Belkin
IdentifiersCVE-2025-7081CWE-78 · Improper Neutralization of Special…

CVE-2025-7081 is a critical OS command injection vulnerability in Belkin F9K1122 firmware version 1.00.33. The issue affects the /goform/formSetWanStatic endpoint in the webs component, specifically the formSetWanStatic function. User-controlled input supplied via the parameters m_wan_ipaddr, m_wan_netmask, m_wan_gateway, m_wan_staticdns1, and m_wan_staticdns2 is passed directly to operating system command execution logic without sufficient sanitization or neutralization of special elements. Because these WAN configuration fields are attacker-controllable, a remote attacker can inject arbitrary shell commands through crafted requests to the vulnerable endpoint.

Do you run this?See affected versions in your environment and whether adversaries are exploiting this vulnerability against assets like yours.
Check your exposure
Analyst brief

Impact, mitigation & remediation

What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.

Impact

What an attacker gets, and what they’ve been doing with it.

Successful exploitation allows remote execution of arbitrary operating system commands in the context of the affected device. This can enable full compromise of the router, including unauthorized reconfiguration of network settings, execution of follow-on payloads, persistence establishment, traffic interception or redirection, and potential use of the device as a foothold for further activity on the local network. Public exploit disclosure increases the likelihood of opportunistic exploitation.

Mitigation

If you can’t patch tonight, do this now.

Restrict access to the router administrative interface and the /goform/ management endpoints to trusted hosts only. Disable remote administration if enabled, place the management interface behind an internal network boundary, and use firewall rules or ACLs to prevent untrusted remote access. Monitor for unexpected configuration changes and signs of command execution on the device. Because public exploit details are available and vendor response is reportedly absent, isolating or decommissioning exposed affected devices is advisable.

Remediation

Patch, then assume compromise.

Upgrade to a vendor-provided fixed firmware version if one becomes available. The vulnerable code path should be remediated by removing shell invocation where possible, using safe APIs for network configuration, and strictly validating and sanitizing all WAN configuration parameters before use. If Belkin has not issued a patch, replacement of the affected device with a supported model should be considered.

Public exploits

Exploits

No public exploits tracked yet. Mallory keeps watching.

View more in app →
No public exploit code observed for this vulnerability. Mallory keeps watching.
Exposure surface

Affected products & vendors

Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.

VendorProductType
BelkinF9k1122 Firmwareoperating_system
FAQ

Frequently asked questions

Is CVE-2025-7081 exploited in the wild?
Yes. As of Sep 25, 2026, Mallory has reports of exploitation in the wild.
Is there a public exploit for CVE-2025-7081?
Yes. As of Sep 25, 2026, Mallory has reports of a public exploit for CVE-2025-7081.
Is there a patch for CVE-2025-7081?
Upgrade to a vendor-provided fixed firmware version if one becomes available. The vulnerable code path should be remediated by removing shell invocation where possible, using safe APIs for network configuration, and strictly validating and sanitizing all WAN configuration parameters before use.
What products are affected by CVE-2025-7081?
Belkin F9k1122 Firmware.
How severe is CVE-2025-7081?
CVE-2025-7081 has a CVSS v4 score of 2.1 (Low) and an EPSS score of 20.4% (98th percentile) as of Sep 25, 2026.
Activity feed

Recent activity

5 sources tracked across advisories and community write-ups. News coverage will land here when it surfaces.

View more in app →

No news coverage yet. Advisories and community discussion only.

Do you run this?See affected versions in your environment and whether adversaries are exploiting this vulnerability against assets like yours.
Check your exposure
Mallory platform

The version that knows your environment.

This page is what’s public. Mallory adds the parts that aren’t: which of your assets are affected, which adversaries are exploiting it right now, and which detections to deploy tonight.
Exposure mappingQuery your assets running an affected version, and investigate the blast radius.
Threat actor evidenceEvery report linking this CVE to a named adversary.
Associated malwareMalware families linked to this CVE, with evidence and IOCs.
Detection signatures2YARA, Sigma, Snort, and vendor rules, auto-deployed to your SIEM.
Vendor-by-vendor mappingCross-references every affected SKU, including bundled OEM variants.
Social activity5Community discussion across Reddit, Mastodon, and other social sources.