CVE-2025-7414: OS Command Injection in Tenda O3V2 /goform/setPingInfo
- Vendor
- Tenda
CVE-2025-7414 is a critical remote command injection vulnerability in Tenda O3V2 firmware version 1.0.0.12(3880). The flaw affects the httpd component, specifically the fromNetToolGet function exposed via the /goform/setPingInfo endpoint. According to the provided content, improper handling of the domain argument allows attacker-controlled input to be incorporated into an operating system command, resulting in OS command injection. The issue is remotely reachable, and public exploit disclosure indicates that exploitation details are available.
Impact, mitigation & remediation
What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.
Impact
What an attacker gets, and what they’ve been doing with it.
Successful exploitation allows a remote attacker to execute arbitrary operating system commands on the affected Tenda O3V2 device. This can lead to full compromise of the device, including unauthorized administrative control, modification of configuration, deployment of malware or botnet payloads, persistence, use of the device as a pivot point, and potential disruption of network services provided by the device.
Mitigation
If you can’t patch tonight, do this now.
Restrict or eliminate remote access to the device management interface, especially exposure of the vulnerable HTTP service to untrusted networks or the public internet. Place affected devices behind firewalls or management VPNs, enforce network segmentation, disable unnecessary administrative interfaces, and monitor for suspicious requests to /goform/setPingInfo. Because public exploit code is reportedly available and the vulnerability is being targeted by botnet activity in the supplied context, internet-exposed devices should be prioritized for containment or isolation.
Remediation
Patch, then assume compromise.
Upgrade the affected Tenda O3V2 device to a vendor-fixed firmware release if one is available. The provided content identifies version 1.0.0.12(3880) as vulnerable; organizations should verify whether Tenda has issued an updated firmware version that corrects input handling in the /goform/setPingInfo functionality and apply it promptly. If no fix is available, replace the device with supported hardware.
Exploits
No public exploits tracked yet. Mallory keeps watching.
Affected products & vendors
Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.
References
Frequently asked questions
- Is CVE-2025-7414 exploited in the wild?
- Yes. As of Oct 16, 2026, Mallory has reports of exploitation in the wild.
- Is there a public exploit for CVE-2025-7414?
- Yes. As of Oct 16, 2026, Mallory has reports of a public exploit for CVE-2025-7414.
- Is there a patch for CVE-2025-7414?
- Upgrade the affected Tenda O3V2 device to a vendor-fixed firmware release if one is available. The provided content identifies version 1.0.0.12(3880) as vulnerable; organizations should verify whether Tenda has issued an updated firmware version that corrects input handling in the /goform/setPingInfo functionality and apply it promptly.
- What products are affected by CVE-2025-7414?
- Tenda O3 Firmware.
- How severe is CVE-2025-7414?
- CVE-2025-7414 has a CVSS v4 score of 2.1 (Low) and an EPSS score of 13.4% (96th percentile) as of Oct 16, 2026.
Recent activity
6 sources tracked across advisories, community write-ups, and news. New activity surfaces here as Mallory finds it.