CVE-2026-129713: Unauthenticated Stack-Based Buffer Overflow in Danfoss AK-SM 8xxA Controllers

Published Nov 20, 2026 · Updated today
Trending this week#70of 434,988 vulnerabilities
Mention activity · 30 days32 mentions · peak 12 in a dayToday
CVSS9.3Critical · v4
EPSS1.9%80th percentile
CISA KEVNoNot listed
In the wildNonePublic exploit, no exploitation reported
IdentifiersCVE-2026-129713CWE-121 · Stack-based Buffer Overflow

CVE-2026-129713 is a stack-based buffer overflow in an unauthenticated CGI handler of Danfoss AK-SM 8xxA Series controllers running software version 5.4.0 or earlier. A remote attacker can trigger the vulnerability using specially crafted HTTP or HTTPS POST requests, causing memory corruption and a webserver restart. Arbitrary code execution with webserver privileges is a hypothetical potential consequence, not a demonstrated outcome. Exploitation requires neither authentication nor user interaction.

Do you run this?See affected versions in your environment and whether adversaries are exploiting this vulnerability against assets like yours.
Check your exposure
Analyst brief

Impact, mitigation & remediation

What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.

Impact

What an attacker gets, and what they’ve been doing with it.

Exploitation can disrupt the controller's web service and interrupt access to its management interface through memory corruption and webserver restarts. Potential arbitrary code execution would occur with the webserver's privileges. Full controller takeover, changes to refrigeration settings, and disruption of physical cooling operations have not been established for this vulnerability; operational consequences depend on the deployment. No known public exploitation was reported when the advisory was published.

Mitigation

If you can’t patch tonight, do this now.

Remove direct public-internet exposure and restrict access to the controller's web interface to authorized systems. Place controllers behind firewalls, isolate control networks from business networks, and permit remote maintenance only through an updated secure VPN or another protected network architecture. Enable Strict Mode as recommended by Danfoss, although it is not established as a complete fix. Use strong, unique account passwords as defense in depth; passwords alone do not prevent exploitation of the unauthenticated handler. Assess effects on monitoring and maintenance before changing network access.

Remediation

Patch, then assume compromise.

Danfoss plans to address the vulnerability in software version 5.5.x. Confirm availability and the exact corrected release through vendor release notes, then upgrade affected controllers. A fixed release was not available at the time of the advisories. Danfoss also plans to remove the option to disable Strict Mode.

Public exploits

Exploits

1 exploit validated by Mallory's analysis.

View more in app →
CVE-2026-129713The supplied repository contains README.md and one standalone Python script, poc.py. The README claims an unauthenticated Danfoss AK-SM stack buffer overflow, identifies CVE-2026-129713, and asserts a CVSS score of 9.8 and possible remote code execution. These claims are not independently substantiated by the supplied material: no firmware versions, vulnerable handler source, crash traces, or successful execution evidence are included. poc.py accepts a target base URL through argparse and calls exploit(). It submits a fixed 300-character string to two CGI endpoints, then requests /index.html. Each request has a 10-second timeout and disables TLS certificate verification. HTTP 500, response text mentioning crashes, and connection errors are treated as possible success indicators. These checks can produce false positives and do not prove a stack overflow; connection errors are not necessarily connection resets or device crashes. The implemented capability is an active, potentially disruptive overflow/crash attempt with basic response inspection, not a demonstrated RCE exploit or a passive detection script. Its hardcoded payload makes it operational only in the limited sense of sending the attempted crash input. No shell payload, exfiltration, persistence, external callback, or framework integration appears in the code. There is no clear evidence that the repository is deliberately fake, but its vulnerability and exploitability claims remain unverified. README image and badge links are documentation resources, not destinations contacted by the Python exploit. Repository URL, git reference, and archive size were not supplied; empty metadata and size 0 indicate unavailable values.cveForge · Disclosed Nov 24, 2026 · python · network · webOperational
FAQ

Frequently asked questions

Is CVE-2026-129713 exploited in the wild?
As of Nov 28, 2026, Mallory has no reports of CVE-2026-129713 being exploited in the wild. It is not listed in CISA KEV.
Is there a public exploit for CVE-2026-129713?
Yes. Mallory tracks 1 public exploit or proof of concept for CVE-2026-129713, the earliest disclosed Nov 24, 2026.
Is there a patch for CVE-2026-129713?
Danfoss plans to address the vulnerability in software version 5.5.x. Confirm availability and the exact corrected release through vendor release notes, then upgrade affected controllers.
How severe is CVE-2026-129713?
CVE-2026-129713 has a CVSS v4 score of 9.3 (Critical) and an EPSS score of 1.9% (80th percentile) as of Nov 28, 2026.
Activity feed

Recent activity

32 sources tracked across advisories, community write-ups, and news. New activity surfaces here as Mallory finds it.

View more in app →
dailysecuNews · Nov 28, 2026마트 냉장·공조 관리하는 댄포스 제어기 취약점…패치 전 외부 접속 차단 권고 < 해외 < 이슈 < 기사본문 - 데일리시큐An unauthenticated vulnerability in Danfoss AK-SM 8xxA refrigeration and HVAC controllers running version 5.4.0 or earlier can disrupt the controller's web service and potentially allow code execution with web-server privileges. Danfoss assigned a CVSS score of 9.3. Effects on physical refrigeration or HVAC operations depend on the installation. A fix is planned for version 5.5.x; interim guidance recommends blocking direct internet access, restricting access between control and office networks, and permitting only approved remote-maintenance paths.Read more ↗computerworld dkNews · Nov 27, 2026Dagens it-nyheder: 27. november 2026 - ComputerworldA critical vulnerability rated CVSS 9.8 in Danfoss AK-SM 8xxA refrigeration control systems. Unauthenticated attackers can restart servers and potentially execute code remotely with webserver privileges. No patch is available according to the report. Recommended mitigations include restricting network access, placing controllers behind a firewall, and using updated VPN solutions for remote access. The article mentions earlier attacks against refrigeration systems but does not explicitly attribute them to this vulnerability.Read more ↗infosecurity magazine newsNews · Nov 26, 2026CISA Urges Action After Danfoss Reveals Critical Flaw in Fridge Contro - Infosecurity MagazineA critical unauthenticated stack-based buffer overflow affecting Danfoss AK-SM 8xxA Series refrigeration controllers, rated CVSS 9.8. Crafted HTTP/S POST requests can cause memory corruption and webserver restarts, with potential arbitrary code execution described as hypothetical. No patch is currently available; a fix is planned for software version 5.5.x. Recommended mitigations include removing direct internet exposure, restricting remote access through a secure VPN or protected network, enabling Strict mode, and using strong, unique passwords. The article describes earlier attacks against Danfoss controllers but does not link them to this vulnerability.Read more ↗cyber security newsNews · Nov 26, 2026Critical Danfoss Refrigeration Controller Flaw Could Allow Remote Code Execution Without AuthenticationA critical stack-based buffer overflow in the unauthenticated web server request handler of Danfoss AK-SM 8xxA refrigeration controllers running software version 5.4.0 or earlier. Rated CVSS 3.1 9.8, it can cause the web server to restart and potentially allow remote code execution with the web server's permissions. Full device control or modification of refrigeration settings is not established. CISA reported no known public exploitation at advisory publication. A fix is planned for version 5.5.x; interim safeguards include enabling Strict Mode, restricting web interface access, network segmentation, firewalls, and protected remote access.Read more ↗
+6 more in the timeline. Sign up to see them
Do you run this?See affected versions in your environment and whether adversaries are exploiting this vulnerability against assets like yours.
Check your exposure
Mallory platform

The version that knows your environment.

This page is what’s public. Mallory adds the parts that aren’t: which of your assets are affected, which adversaries are exploiting it right now, and which detections to deploy tonight.
Exposure mappingQuery your assets running an affected version, and investigate the blast radius.
Threat actor evidenceEvery report linking this CVE to a named adversary.
Associated malwareMalware families linked to this CVE, with evidence and IOCs.
Detection signaturesYARA, Sigma, Snort, and vendor rules, auto-deployed to your SIEM.
Vendor-by-vendor mappingCross-references every affected SKU, including bundled OEM variants.
Social activity20Community discussion across Reddit, Mastodon, and other social sources.