CVE-2026-5830: Stack-based Buffer Overflow in Tenda AC15 /goform/SysToolChangePwd
- Vendor
- Tenda
CVE-2026-5830 affects Tenda AC15 firmware version 15.03.05.18. The vulnerability is in the websGetVar function used by the /goform/SysToolChangePwd endpoint. According to the provided content, improper handling of the oldPwd, newPwd, or cfmPwd request arguments can trigger a stack-based buffer overflow. The issue is remotely exploitable, and public exploit code is reported to be available.
Impact, mitigation & remediation
What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.
Impact
What an attacker gets, and what they’ve been doing with it.
Successful exploitation can cause memory corruption in the affected process and may enable an attacker to compromise confidentiality, integrity, and availability on the device. The provided severity metadata indicates high impact across C, I, and A. Because the flaw is a stack-based buffer overflow in a remotely reachable password-change handler, exploitation may plausibly result in process crash, denial of service, or potentially arbitrary code execution in the security context of the vulnerable service; however, the provided content does not explicitly confirm code execution.
Mitigation
If you can’t patch tonight, do this now.
Restrict network access to the device management interface, especially any exposure of /goform/SysToolChangePwd from untrusted networks. Disable remote administration if not required, place the management plane behind a trusted internal segment or VPN, and enforce ACLs/firewall rules limiting access to authorized administrators only. Monitor for anomalous requests to the password-change endpoint and consider IDS/IPS signatures for oversized oldPwd/newPwd/cfmPwd parameters until a patch is applied.
Remediation
Patch, then assume compromise.
Upgrade Tenda AC15 devices from firmware version 15.03.05.18 to a vendor-fixed release if one is available. If no patched firmware has been published, apply the latest vendor firmware and monitor Tenda advisories for a security update addressing CVE-2026-5830. Validate that the /goform/SysToolChangePwd handler properly bounds-checks oldPwd, newPwd, and cfmPwd inputs before deployment of any fix.
Exploits
No public exploits tracked yet. Mallory keeps watching.
Affected products & vendors
Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.
References
Frequently asked questions
- Is CVE-2026-5830 exploited in the wild?
- As of Sep 25, 2026, Mallory has no reports of CVE-2026-5830 being exploited in the wild. It is not listed in CISA KEV.
- Is there a public exploit for CVE-2026-5830?
- Yes. As of Sep 25, 2026, Mallory has reports of a public exploit for CVE-2026-5830.
- Is there a patch for CVE-2026-5830?
- Upgrade Tenda AC15 devices from firmware version 15.03.05.18 to a vendor-fixed release if one is available. If no patched firmware has been published, apply the latest vendor firmware and monitor Tenda advisories for a security update addressing CVE-2026-5830.
- What products are affected by CVE-2026-5830?
- Tenda Ac15 Firmware.
- How severe is CVE-2026-5830?
- CVE-2026-5830 has a CVSS v4 score of 7.4 (High) and an EPSS score of 0.64% (51st percentile) as of Sep 25, 2026.
Recent activity
5 sources tracked across advisories, community write-ups, and news. New activity surfaces here as Mallory finds it.