Skip to main content
Mallory
HighPublic exploitVulnerability

CVE-2026-5990: Stack-based Buffer Overflow in Tenda F451 /goform/SafeEmailFilter fromSafeEmailFilter

Published Apr 9, 2026 · Updated 2 months ago
Trending this weekNot trendingOutside this week’s top 100
Mention activity · 30 daysNo mention activity in the last 30 days.
CVSS7.4High · v4
EPSS0.52%45th percentile
CISA KEVNoNot listed
In the wildNonePublic exploit, no exploitation reported
Vendor
Tenda
IdentifiersCVE-2026-5990CWE-121 · Stack-based Buffer Overflow

CVE-2026-5990 affects Tenda F451 firmware version 1.0.0.7. The vulnerability is in the fromSafeEmailFilter function associated with the /goform/SafeEmailFilter endpoint. According to the provided content, improper handling of the page argument allows crafted input to trigger a stack-based buffer overflow. The issue is remotely reachable, and public exploit disclosure has been noted.

Do you run this?See affected versions in your environment and whether adversaries are exploiting this vulnerability against assets like yours.
Check your exposure
Analyst brief

Impact, mitigation & remediation

What it means and what to do now: patch path, interim mitigations, and the assume-compromise checklist.

Impact

What an attacker gets, and what they’ve been doing with it.

Successful exploitation can cause memory corruption in the affected process and may result in compromise of confidentiality, integrity, and availability. Based on the provided CVSS vectors and the nature of a stack-based buffer overflow, exploitation may enable an attacker to crash the service or device and potentially execute arbitrary code in the context of the vulnerable component, although the provided content does not explicitly confirm code execution.

Mitigation

If you can’t patch tonight, do this now.

Restrict network access to the device management interface and specifically to the /goform/SafeEmailFilter endpoint from untrusted networks. Disable remote administration if not required, place the device behind trusted management networks only, and enforce ACLs/firewall rules to limit access to authenticated administrative sources. Monitor for suspicious requests targeting /goform/SafeEmailFilter and anomalous crashes or reboots that may indicate exploitation attempts.

Remediation

Patch, then assume compromise.

Upgrade Tenda F451 firmware from version 1.0.0.7 to a vendor-fixed release if one is available. If no patched firmware is currently available, apply any vendor-issued hotfix or updated image addressing CVE-2026-5990. Review vendor advisories and validate that the /goform/SafeEmailFilter handler properly bounds-checks and sanitizes the page parameter before deployment.

Public exploits

Exploits

No public exploits tracked yet. Mallory keeps watching.

View more in app →
No public exploit code observed for this vulnerability. Mallory keeps watching.
Exposure surface

Affected products & vendors

Products and vendors Mallory has correlated with this vulnerability. Open in Mallory to drill down to specific CPE configurations and version ranges.

VendorProductType
TendaF451 Firmwareoperating_system
FAQ

Frequently asked questions

Is CVE-2026-5990 exploited in the wild?
As of Sep 25, 2026, Mallory has no reports of CVE-2026-5990 being exploited in the wild. It is not listed in CISA KEV.
Is there a public exploit for CVE-2026-5990?
Yes. As of Sep 25, 2026, Mallory has reports of a public exploit for CVE-2026-5990.
Is there a patch for CVE-2026-5990?
Upgrade Tenda F451 firmware from version 1.0.0.7 to a vendor-fixed release if one is available. If no patched firmware is currently available, apply any vendor-issued hotfix or updated image addressing CVE-2026-5990.
What products are affected by CVE-2026-5990?
Tenda F451 Firmware.
How severe is CVE-2026-5990?
CVE-2026-5990 has a CVSS v4 score of 7.4 (High) and an EPSS score of 0.52% (45th percentile) as of Sep 25, 2026.
Activity feed

Recent activity

4 sources tracked across advisories, community write-ups, and news. New activity surfaces here as Mallory finds it.

View more in app →
Do you run this?See affected versions in your environment and whether adversaries are exploiting this vulnerability against assets like yours.
Check your exposure
Mallory platform

The version that knows your environment.

This page is what’s public. Mallory adds the parts that aren’t: which of your assets are affected, which adversaries are exploiting it right now, and which detections to deploy tonight.
Exposure mappingQuery your assets running an affected version, and investigate the blast radius.
Threat actor evidenceEvery report linking this CVE to a named adversary.
Associated malwareMalware families linked to this CVE, with evidence and IOCs.
Detection signaturesYARA, Sigma, Snort, and vendor rules, auto-deployed to your SIEM.
Vendor-by-vendor mappingCross-references every affected SKU, including bundled OEM variants.
Social activity3Community discussion across Reddit, Mastodon, and other social sources.